Hematology Analyzer

  • Throughput 60 Test/Hour
  • 21 Parameters + Three Histogram
  • Two Reagent System
  • Integrated Work Station
  • 0” Color LED Touch Screen
  • Automatic Reagent Management System
  • Advance Fludics Design For Stable Performance
  • Direct Laser Colour Printer Connectivity (optional)
  • P-LCR & P-LCC Parameters to differentiate Platalets Clumps & Mega Thrombocytes

Hematology Analyzer Pdf

Parameters

  • Na+ / K+ / Ca++
  • Na+ / k+ / CI
  • Na+ / K+ / CI / Ca++
  • Na+ / K+ / CI / Ca++ / Ph

Features

  • Ready 24X7
  • Easy to use
  • Low running cost/test
  • Result in a minute
  • All types of samples
  • Reliable result
  • Easy to maintain

Specifications

  • Analysis Principle = Ion Selective Electrodes
  • Analysis time = Less than a minute
  • Throughput = 60 test/hour
  • Calibration = Automatic , 2 point or user Selectable
  • Calibrators = Calibrator 1 (500ml) & (100ml) Pack , Individual bottle system
  • Rinse method = Automatic
  • Patient ID = Auto increment or user selectable
  • Power requirement = 165-242-V , 50-60 , <35VA Temperature = 10oC – 40oC .
  • Humidity > 85%
  • Sample type = Whole blood . Serum , Plasma & Diluted Urine
  • Sample input = From Syringe , tube & capillary

Fluorescence Immunoassay Analyzer

  • Robust

FIA Analyzer has powerful system to allow checking machine itself every time when power on, besides, remote software upgrade allowed when update.

  • Accurate and Rapid

Test results come out in 3 to 20 min, repeatability: CV<3%, accuracy>85%, linear correlation coefficient r>0.99.

  • Intelligent

The analyzer can automatically identify each item and match the SD card information.

  • Powerful

Rapid test model and standard test model allowed, 5000 test results data capacity.

 

Fluorescence Immunoassay Analyzer Pdf

RS-125

• Effective temperature regulation system with Peltier controlled cuvette / flow cell block.
• Dual reading mode.
• Rebust system with built in stabilizer.
• Latest technology with battery back up for 255 tests with 30 results saved in each 3 levels of QC.
• Capacity of saving 2500 test results.
• Rebust in built 20 column Thermal Printer with 384 stationary heads.
• Unique circuitry for long lamp life.
• Reliable peristaltic pump with maintenance free operations.
• Sophisticated software for kinetic graph with built in delta calculation for saturated ( high).
• Samples from graphic display without diluting and rerunning the samples.
• Monochromatic , Bichromatic Measurement.
• Multi Standard Calibration.
• Patients ID entry.
• Editing of saved tests.
• Levy jennings and standards deviation graphs.
• Optional interface for External Printer.
• Access to Test by Touch of Key.
• Resolution of saving 4 decimal points.
• User defined temperature 20O C to 40O C.
• On-line graph in Fixtime and kinetic mode.
• Online data output for LIS communication through RS232 Serial port .
• TURB option is provided on the ‘ Select Test ‘ screen in order to access Prieturb Test easily.

*BAS-120TS*

This Biochemistry Analyzer can test samples in two ways, by suction pump and by disposable cuvette

Clinical Biochemistry touch screen analyzer with incubator temperature control and internal printer BAS-12TS is a TOUCH SCREEN Microprocessor biochemical analyzer, which increase over 50 biological indicators.

Features

  • New Version
  • Lamp Standby Function
  • 24V Universal Power Supply
  • Powerful Software
  • Multi-Language
  • USB Port for external printer, online operation, keyboard, software update (optional)
  • AD Auto Zero
  • 0” Touch Screen
  • Auto temperature Control
  • Built-in Printer
  • Very Easy to use, user friendly interface, requiring minimal training or supervision to get started.

50 Biochemistry tests

BAS-120TS.PDF

Thrombostat (Behnk EleKtronik-Germany)

Our specialists for whole blood

FEATURES

  • Easy to use
  • Designed for both laboratory and mobile use
  • Can determine all coagulation parameters
  • Maintenance-free
thromo

PRINICPLE

Starting

When switched on, the thrombostat automatically checks all important functions.

Incubating

The measuring cuvette, with the sample or reagent, is placed into one of the incubation positions.

Measuring

Upon completion of incubation, the cuvette is placed in the measuring channel. The measurement is then started by using either a special Star-pipette or by using the countdown timer in connection with any commercial pipette. Upon completion of the measurement, the result are automatically calculated are displayed.

EFFECTIVE

The mechanical measuring system

  • A sensor monitors the ball rotating on the bottom of the cuvette.
  • Three parameters lead to the positive detection of a developing coagulum:-
  • A large coagulum is created which stops the ball on the wall of the cuvette.
  • A softer, slower coagulum build-up directs the ball towards the Centre of the cuvette.

A change in the samples viscosity causes a delay in the balls movement.

The Flexibility

In the laboratory, at the patients house, or on the move: The Thrombostat can be used almost anywhere. It works with all standard reagents and sample types.

Thrombostat- Syris.PDF